• 调试类加载
    • Overview of Classloading in Flink
    • Inverted Class Loading and ClassLoader Resolution Order
    • Avoiding Dynamic Classloading for User Code
    • Manual Classloading in User Code
    • X cannot be cast to X exceptions
    • Unloading of Dynamically Loaded Classes in User Code
    • Resolving Dependency Conflicts with Flink using the maven-shade-plugin.

    调试类加载

    • Overview of Classloading in Flink
    • Inverted Class Loading and ClassLoader Resolution Order
    • Avoiding Dynamic Classloading for User Code
    • Manual Classloading in User Code
    • X cannot be cast to X exceptions
    • Unloading of Dynamically Loaded Classes in User Code
    • Resolving Dependency Conflicts with Flink using the maven-shade-plugin.

    When running Flink applications, the JVM will load various classes over time.These classes can be divided into three groups based on their origin:

    • The Java Classpath: This is Java’s common classpath, and it includes the JDK libraries, and all codein Flink’s /lib folder (the classes of Apache Flink and some dependencies).

    • The Flink Plugin Components: The plugins code in folders under Flink’s /plugins folder. Flink’s plugin mechanism will dynamically load them once during startup.

    • The Dynamic User Code: These are all classes that are included in the JAR files of dynamically submitted jobs,(via REST, CLI, web UI). They are loaded (and unloaded) dynamically per job.

    As a general rule, whenever you start the Flink processes first and submit jobs later, the job’s classes are loaded dynamically.If the Flink processes are started together with the job/application, or if the application spawns the Flink components (JobManager, TaskManager, etc.), then all job’s classes are in the Java classpath.

    Code in plugin components is loaded dynamically once by a dedicated class loader per plugin.

    In the following are some more details about the different deployment modes:

    Standalone Session

    When starting a Flink cluster as a standalone session, the JobManagers and TaskManagers are started with the Flink framework classes in theJava classpath. The classes from all jobs/applications that are submitted against the session (via REST / CLI) are loaded dynamically.Docker / Kubernetes Sessions

    Docker / Kubernetes setups that start first a set of JobManagers / TaskManagers and then submit jobs/applications via REST or the CLIbehave like standalone sessions: Flink’s code is in the Java classpath, plugin components are loaded dynamically at startup and the job’s code is loaded dynamically.

    YARN

    YARN classloading differs between single job deployments and sessions:

    • When submitting a Flink job/application directly to YARN (via bin/flink run -m yarn-cluster …), dedicated TaskManagers andJobManagers are started for that job. Those JVMs have user code classes in the Java classpath.That means that there is no dynamic classloading involved in that case for the job.

    • When starting a YARN session, the JobManagers and TaskManagers are started with the Flink framework classes in theclasspath. The classes from all jobs that are submitted against the session are loaded dynamically.

    Mesos

    Mesos setups following this documentation currently behave very much like the aYARN session: The TaskManager and JobManager processes are started with the Flink framework classes in the Java classpath, jobclasses are loaded dynamically when the jobs are submitted.

    Inverted Class Loading and ClassLoader Resolution Order

    In setups where dynamic classloading is involved (plugin components, Flink jobs in session setups), there is a hierarchy of typically two ClassLoaders: (1) Java’s application classloader, which has all classes in the classpath, and (2) the dynamic plugin/user code classloader.for loading classes from the plugin or the user-code jar(s). The dynamic ClassLoader has the application classloader as its parent.

    By default, Flink inverts classloading order, meaning it looks into the dynamic classloader first, and only looks intothe parent (application classloader) if the class is not part of the dynamically loaded code.

    The benefit of inverted classloading is that plugins and jobs can use different library versions than Flink’s core itself, which is veryuseful when the different versions of the libraries are not compatible. The mechanism helps to avoid the common dependency conflicterrors like IllegalAccessError or NoSuchMethodError. Different parts of the code simply have separate copies of theclasses (Flink’s core or one of its dependencies can use a different copy than the user code or plugin code).In most cases, this works well and no additional configuration from the user is needed.

    However, there are cases when the inverted classloading causes problems (see below, “X cannot be cast to X”). For user code classloading, you can revert back to Java’s default mode by configuring the ClassLoader resolution order viaclassloader.resolve-order in the Flink config to parent-first(from Flink’s default child-first).

    Please note that certain classes are always resolved in a parent-first way (through the parent ClassLoader first), because theyare shared between Flink’s core and the plugin/user code or the plugin/user-code facing APIs. The packages for these classes are configured via classloader.parent-first-patterns-default andclassloader.parent-first-patterns-additional.To add new packages to be parent-first loaded, please set the classloader.parent-first-patterns-additional config option.

    Avoiding Dynamic Classloading for User Code

    All components (JobManger, TaskManager, Client, ApplicationMaster, …) log their classpath setting on startup.They can be found as part of the environment information at the beginning of the log.

    When running a setup where the Flink JobManager and TaskManagers are exclusive to one particular job, one can put user code JAR filesdirectly into the /lib folder to make sure they are part of the classpath and not loaded dynamically.

    It usually works to put the job’s JAR file into the /lib directory. The JAR will be part of both the classpath(the AppClassLoader) and the dynamic class loader (FlinkUserCodeClassLoader).Because the AppClassLoader is the parent of the FlinkUserCodeClassLoader (and Java loads parent-first, by default), this shouldresult in classes being loaded only once.

    For setups where the job’s JAR file cannot be put to the /lib folder (for example because the setup is a session that isused by multiple jobs), it may still be possible to put common libraries to the /lib folder, and avoid dynamic class loadingfor those.

    Manual Classloading in User Code

    In some cases, a transformation function, source, or sink needs to manually load classes (dynamically via reflection).To do that, it needs the classloader that has access to the job’s classes.

    In that case, the functions (or sources or sinks) can be made a RichFunction (for example RichMapFunction or RichWindowFunction)and access the user code class loader via getRuntimeContext().getUserCodeClassLoader().

    X cannot be cast to X exceptions

    In setups with dynamic classloading, you may see an exception in the style com.foo.X cannot be cast to com.foo.X.This means that multiple versions of the class com.foo.X have been loaded by different class loaders, and types of that class are attempted to be assigned to each other.

    One common reason is that a library is not compatible with Flink’s inverted classloading approach. You can turn off inverted classloadingto verify this (set classloader.resolve-order: parent-first in the Flink config) or excludethe library from inverted classloading (set classloader.parent-first-patterns-additionalin the Flink config).

    Another cause can be cached object instances, as produced by some libraries like Apache Avro, or by interning objects (for example via Guava’s Interners).The solution here is to either have a setup without any dynamic classloading, or to make sure that the respective library is fully part of the dynamically loaded code.The latter means that the library must not be added to Flink’s /lib folder, but must be part of the application’s fat-jar/uber-jar

    Unloading of Dynamically Loaded Classes in User Code

    All scenarios that involve dynamic user code classloading (sessions) rely on classes being unloaded again.Class unloading means that the Garbage Collector finds that no objects from a class exist and more, and thus removes the class(the code, static variable, metadata, etc).

    Whenever a TaskManager starts (or restarts) a task, it will load that specific task’s code. Unless classes can be unloaded, this willbecome a memory leak, as new versions of classes are loaded and the total number of loaded classes accumulates over time. Thistypically manifests itself though a OutOfMemoryError: Metaspace.

    Common causes for class leaks and suggested fixes:

    • Lingering Threads: Make sure the application functions/sources/sinks shuts down all threads. Lingering threads cost resources themselves andadditionally typically hold references to (user code) objects, preventing garbage collection and unloading of the classes.

    • Interners: Avoid caching objects in special structures that live beyond the lifetime of the functions/sources/sinks. Examples are Guava’sinterners, or Avro’s class/object caches in the serializers.

    A way to address dependency conflicts from the application developer’s side is to avoid exposing dependencies by shading them away.

    Apache Maven offers the maven-shade-plugin, which allows one to change the package of aclass after compiling it (so the code you are writing is not affected by the shading). For example if you have the com.amazonaws packages fromthe aws sdk in your user code jar, the shade plugin would relocate them into the org.myorg.shaded.com.amazonaws package, so that your code is calling your aws sdk version.

    This documentation page explains relocating classes using the shade plugin.

    Note that most of Flink’s dependencies, such as guava, netty, jackson, etc. are shaded away by the maintainers of Flink, so users usually don’t have to worry about it.